Firestop installation · Dublin and surrounding counties

Install-only fire stopping. To the issued details.

Labour and certified materials installed to the drawings and specification you issue. For main contractors and M&E subcontractors on new-build and fit-out packages.

  • Install only
  • No design duty
  • BCAR install ancillary
  • Dublin
  • Meath
  • Kildare
  • Wicklow
  • Louth

Scope of works

What is in

You hold the fire strategy, specification and drawings. We install to them. The quotation is labour and certified materials against the issued design.

IN

Labour

Site labour to install the seals shown on the issued drawings. Operatives hold SOLAS Safe Pass. RAMS are issued before works commence.

IN

Certified materials

Manufacturer-tested systems named on your specification. Product evidence — data sheets, Declarations of Performance, and test / ETA documents — as specified.

IN

To issued details

Penetrations, linear joints and cavity barriers as drawn. Missing details are referred to the design party. We do not invent or substitute details on site.

Scope exclusions

What is out

Exclusions are stated so the subcontract matches the works. Print the IN / OUT page with a quotation if useful.

OUT

No design

We do not select systems or approve the fire strategy. Variations that require a new detail are referred to the designer.

OUT

No surveys

We do not survey buildings to locate openings. A find-all-penetrations duty is not included in the quotation.

OUT

No design duty

The contract states that we carry no design responsibility. We do not hold professional indemnity for design. We do not sign design ancillaries.

OUT

Design partner

Design or survey can sit with a partner on a separate contract. The quotation remains for installation only.

Commercial

How a quotation is prepared

01

Submit the documents

Drawings, fire specification and schedules. We price from what is issued.

02

Labour and materials

Certified systems named on the specification. Not a design fee.

03

Provisional sums

Unspecified openings are treated as provisional. We do not search the building for additional openings.

04

Handover pack

Photographs, seal register, and an install-to-details ancillary for the Assigned Certifier.

Documents

What you send

A quotation is prepared from the pack you issue. If a document is not available, say so — we will state the assumption or a provisional sum.

  • Issued drawings — compartmentation, services, details
  • Fire specification or fire strategy extracts
  • Penetration or joint schedules where they exist
  • Named tested systems, if already specified
  • Programme window and site access notes
  • County / site address

BCAR

Handover artefacts

Install-only does not mean an absence of paperwork. It means we do not issue a design certificate. The Assigned Certifier still requires evidence that the installation matches the issued details.

Photo log

Before, during and after. Referenced to seal IDs so the pack can be read against the register.

Seal register

ID, location, system, date, installer. The record used by the O&M file and the Assigned Certifier.

Product file

Data sheets, Declarations of Performance, and fire test / ETA evidence for the systems installed.

Install ancillary

Construction ancillary certificate: installation to issued details only. Not a design ancillary.

Seal IDLocationSubstrateSystemDateInstaller
R2-L3-014Riser 2, level 3, northMasonry wallAs specified
R2-L3-015Riser 2, level 3, northMasonry wallAs specified
C1-L1-008Corridor 1, level 1Shaft wallAs specified
HW-L4-003Head of wall, level 4DryliningAs specified

Specimen layout — not a live project. See the handover pack.

Irish frame

TGD B / Part B / BCAR

Fire stopping on this site is described in Irish terms. We do not work to UK documents or forms.

TGD B / Part B

Fire-stopping maintains compartmentation at service openings as Technical Guidance Document B requires. The fire strategy and details belong to the design team.

BCAR

Construction ancillary certificate for installation to issued details. Photo log and seal register for the Assigned Certifier. Not a design ancillary.

Not UK ADB

We do not work to Approved Document B. Irish language and Irish forms only.

FAQ

Questions we are asked

No. We are install-only. We supply labour and certified materials and install to drawings and specifications issued by others. We do not accept design responsibility.

No. We do not survey buildings, locate missing penetrations, or select systems. Where a project requires a survey or design, that work can sit with a partner on a separate contract. Our quotation remains for installation only.

Issued drawings, the fire specification or fire strategy extracts, and penetration or joint schedules where they exist. Unspecified openings are treated as provisional sums, not as an open-ended search of the building.

Dublin, Meath, Kildare, Wicklow and Louth. Base: A83 FC42, Ardnamullan, Clonard, Co. Meath (Enfield / Summerhill).

Yes, for the installation. Photo log, seal register, specified product evidence, and a construction ancillary certificate stating installation to issued details only. We do not sign design ancillaries.

TGD B, Part B and BCAR. Fire-stopping maintains compartmentation at service openings as TGD B requires. We do not work to UK Approved Document B.

The query is referred to the design party. We do not invent or substitute a firestop detail on site. Installation of that opening waits until a detail is issued. That may be a variation.

No. We install what is shown on the issued drawings and schedules. A find-all-penetrations duty is not included. Unspecified openings are priced as provisional sums, not as an open-ended hunt.

Quotation

Request a quotation

Main contractors and M&E subcontractors: please provide the site location and the documents you can issue. We quote for installation only.

Please include the site location and the drawings or specifications available for pricing.

Alternatively, call +353 87 919 9059 or email dean@lineach.com.